Use of cable

Instrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground.

Special features

  • more steady at higher frequencies and temperatures (+90°C) by XLPE core insulation (cross-linked PE)
  • high crosstalk and low cable attenuation
  • largely resistant to acids, bases and usual oils
  • Oil resitance: ICEA S-73-532 / NEMA WC 57-2004 § 6.9.3; standard EN50228-7
  • triple protection for high mechanical requirements and magnetic shield (oxidation-proofed steel wire braid and additional inner sheath)
  • Sunlight resitance: UL 1581 Section 1200
  • flame-retardant acc. IEC60332-1-2 and IEC60332-3-24 (Cat. C)
  • single element & overall shield

Remarks

  • conform to RoHS; conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • suisuitable for intrinsically safe systems zone 1+2 group II acc. IEC 60079-14
  • we are pleased to produce special versions e.g. fire-resistant (Mica), halogen-free, oil- and chemical-resistant (lead sheath or GuardSheath - unleaded), BS 5308, MESC etc. >> also available as compensation cable > INDUTHERM <<
Conductor material: Bare copper strand
Conductor class: 7-wired construction acc. to IEC 60228 cl. 2
Core insulation: XLPE (cross-linked polyethylene)
Core identification: Pairs: single-coloured with numerals: core A black, core B: white; triple: core A: white, core B: red, core C: black, core A and C with numerals
Stranding: Pairs stranded in layers
Shield: Pairs in metal foil (PiMf) with subjacent tinned drain wire 0.6mm
Inner sheath material: PVC, black
Shield3: Steel wire braid, galvanized (SWB)
Outer sheath: PVC
Sheath colour: Black or blue RAL 5015 for intrinsically safe systems
Rated voltage: 300 V
Testing voltage: 1,5 kV
Conductor resistance: 0.5mm² max.36.7 Ω/km; 0.75mm² max.25.0 Ω/km; 1.3mm² max.14.2 Ω/km
Insulation resistance: Min. 5 GΩ x km
Current-carrying-capacity: Acc. to DIN VDE, s. Techn. Guidelines
Capacity: Max.115 nF/km
Inductivity: Ca. 1 mH/km
Coupling: Max. 500 pF/500 m
Min. bending radius fixed: 10 x d
Operat. temp. fixed min/max: -40 °C / +70°C
Operat. temp. moved min/max: -5°C / +50°C
Burning behavior: Self-extinguishing and flame-retardant acc. to IEC 60332-1-2 and IEC 60332-3-24 (Cat. C)
Resistant to oil: ICEA S-73-532 / NEMA WC 57-2004 § 6.9.3

Table of items

Product No.
Dimension
[n x mm²]
Outer-Ø
[mm]
Cu-Index
[kg/km]
Weight
[kg/1.000]
Sheath colour
Variant
2001304 2 X 2 X 0,5 12,4 33,0 226,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001305 4 X 2 X 0,5 13,4 62,0 279,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001308 8 X 2 X 0,5 17,2 119,0 409,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001309 12 X 2 X 0,5 19,4 176,0 533,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001312 16 X 2 X 0,5 21,8 233,0 653,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001313 24 X 2 X 0,5 25,4 348,0 932,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001316 2 X 2 X 0,75 13,2 43,0 256,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001317 4 X 2 X 0,75 14,6 82,0 336,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001320 8 X 2 X 0,75 18,4 160,0 491,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001321 12 X 2 X 0,75 21,3 237,0 645,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001324 16 X 2 X 0,75 23,9 315,0 816,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001325 24 X 2 X 0,75 27,9 470,0 1.136,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001328 2 X 2 X 1,3 15,4 68,0 348,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001332 8 X 2 X 1,3 21,8 239,0 655,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001333 12 X 2 X 1,3 25,4 353,0 930,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001336 16 X 2 X 1,3 28,5 468,0 1.177,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001337 24 X 2 X 1,3 33,9 697,0 1.604,0 black V1: INDUCOM RE-2X(ST)YSWBY-FL PiMF - schwarz / black
2001303 2 X 2 X 0,5 12,4 33,0 226,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001306 4 X 2 X 0,5 13,4 62,0 279,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001307 8 X 2 X 0,5 17,2 119,0 409,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001310 12 X 2 X 0,5 19,4 176,0 533,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001311 16 X 2 X 0,5 21,8 233,0 653,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001314 24 X 2 X 0,5 25,4 348,0 932,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001315 2 X 2 X 0,75 13,2 43,0 256,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001318 4 X 2 X 0,75 14,6 82,0 336,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001319 8 X 2 X 0,75 18,4 160,0 491,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001322 12 X 2 X 0,75 21,3 237,0 645,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001323 16 X 2 X 0,75 23,9 315,0 816,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001326 24 X 2 X 0,75 27,9 470,0 1.136,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001327 2 X 2 X 1,3 15,4 68,0 348,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001330 4 X 2 X 1,3 16,7 124,0 431,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001331 8 X 2 X 1,3 21,8 239,0 655,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001334 12 X 2 X 1,3 25,4 353,0 930,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001335 16 X 2 X 1,3 28,5 468,0 1.177,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue
2001338 24 X 2 X 1,3 33,9 697,0 1.604,0 blue V2: INDUCOM RE-2X(ST)YSWBY-FL PiMf - blau / blue